datasheet,schematic,electronic components, service manual,repairs,tv,monitor,service menu,pcb design
Schematics 4 Free
Service manuals, schematics, documentation, programs, electronics, hobby ....


registersend pass
Bulgarian - schematics repairs service manuals SearchBrowseUploadWanted

Now downloading free:Agilent 5990-9139EN Oscilloscopes in Aerospace Defense Debugging ARINC 429 Serial Buses - Flyer c20140828 [2

Agilent 5990-9139EN Oscilloscopes in Aerospace Defense Debugging ARINC 429 Serial Buses - Flyer c20140828 [2 free download

Various electronics service manuals

File information:
File name:5990-9139EN Oscilloscopes in Aerospace Defense Debugging ARINC 429 Serial Buses - Flyer c20140828 [2
[preview 5990-9139EN Oscilloscopes in Aerospace Defense Debugging ARINC 429 Serial Buses - Flyer c20140828 [2]
Size:1113 kB
Extension:pdf
Mfg:Agilent
Model:5990-9139EN Oscilloscopes in Aerospace Defense Debugging ARINC 429 Serial Buses - Flyer c20140828 [2 🔎
Original:5990-9139EN Oscilloscopes in Aerospace Defense Debugging ARINC 429 Serial Buses - Flyer c20140828 [2 🔎
Descr: Agilent 5990-9139EN Oscilloscopes in Aerospace Defense Debugging ARINC 429 Serial Buses - Flyer c20140828 [2].pdf
Group:Electronics > Other
Uploaded:16-11-2021
User:Anonymous
Multipart:No multipart

Information about the files in archive:
Decompress result:OK
Extracted files:1
File name 5990-9139EN Oscilloscopes in Aerospace Defense Debugging ARINC 429 Serial Buses - Flyer c20140828 [2

Keysight Technologies Oscilloscopes in Aerospace/Defense Debugging ARINC 429 serial buses The Keysight Technologies, Inc. InfiniiVision 3000 and 4000 X-Series oscilloscopes provide ARINC 429 triggering and decoding, as well as eye-diagram mask test capability to help you accelerate debug of your ARINC 429 buses. The differential 12.5 kbps and 100 kbps ARINC 429 serial Figure 1 shows the display of a Keysight InfiniiVision X-Series buses are widely used today in a broad range of commercial scope capturing and decoding a stream of ARINC 429 serial aircraft including many Boeing and Airbus aircraft, as well as bus traffic. All captured words are decoded and displayed in a future Chinese commercial aircraft currently under develop- time-correlated trace below the captured waveform showing the ment. Due to the harsh electrical environment of commercial label field decoded in octal, 2-bit SDI and SSM fields decoded in aircraft, testing the quality of received and transmitted signals binary, and the data field decoded in either hexadecimal or binary is very important. The primary measurement tool that engineers (user-selectable). In addition, the scope can display a tabular list and technicians use today to test the signal integrity of serial of decoded data in the upper half of the scope's display. buses is an oscilloscope. But capturing and measuring the electrical characteristics of ARINC 429 signals have been a The trigger condition for this particular measurement was to difficult and tedious process using conventional analog or trigger on words with a label value of 076 (octal). This word is digital oscilloscopes. Setting up a scope to trigger and shown at center-screen. The next captured word was decoded as synchronize on specific transmitted or received words often a GAP error word (color-coded in red). Using the scope's timing requires an external synchronization signal or guessing at a cursors, we can see that time between these two words was less specific trigger hold-off setting. And then to determine the than the minimum gap time specification of 4 bit times. With this message transfer information of captured and displayed information provided by the scope, it should now be much easier communication packets/words requires a commonly used visual for the avionics engineer or technician to troubleshoot the root "bit-counting" technique, which is slow and prone to errors. cause of this error. Although ARINC 429 bus monitors/protocol analyzers can provide the high-level protocol layer information regarding transfer of data, they tell you nothing about signal integrity. The answer to this dilemma (scope versus bus monitor) is to use a scope that is also able to intelligently trigger on and decode ARINC 429 signals. Figure 1. Decoding a differen



>> Download document << eServiceInfo Context Help



Was this file useful ? Share Your thoughts with the other users.

User ratings and reviews for this file:

DateUserRatingComment

Average rating for this file: 0.00 ( from 0 votes)


Similar Service Manuals :
Agilent ReleaseNotes SW ReleaseNotes SW Desktop A050220121101 - Agilent README.txt README DEE A.05.00.2012.0630 - Agilent nc param - Agilent ReleaseNotes SW ReleaseNotes SW A050320130124 - Agilent ReleaseNotes FW A.05.00.2012.0710.txt ReleaseNotes FW A.05.00.2012.0710 - Agilent Release Note FW A.05.04.2013.0328 ReleaseNotes FW A0504 20130328 - Agilent ReleaseNotes SW ReleaseNotes SW A.05.00.2012.0630 -
 FB -  Links -  Info / Contacts -  Forum -   Last SM download : AIWA NSX-500 ; XG-500 ; CX 3500

script execution: 0.12 s