Text preview for : GuardAware.pdf part of Guardaware CU-22 Guardaware CU-22 burglar alarm manual.



Back to : GuardAware.pdf | Home

~W.ARE

INC. 277 Elm Slreet Bridgewater, MA02324

Tel: (617) 697-3355

CU-22SB
THE HIG~ QUALITY FIELD PROVEN CU-22 COMBINATION BURGLAR/FIRE ALARM CONTR9,L P~NEL PACKAGED IN AN
ALTERNATE SMALLER 11"x12'x3~' KEY-LOCKED CABINET
FOR LOWER PRICING, 12v 40VA TRANSFORMER INCLUDED.
NOTE: - THE ~XISTING CU-22T (LARGE CABINET VERSION) IS STILL AVAILABLE,

FEATURES

*

CABINET DOOR HAS PRINTED LEGEND AND HOLES PUNCH~D FOR KEY SWITCH, RED ~ STATUS AND GREEN LQQE STATUS LED CARTRIDGES (#2L40) TO PROVIDE OPTIONAL BOX MOUNTING FOR SINGLE KEY STATION RESIDENTIAL AND COMMERCIAL INSTALLATIONS, (CABINET COMES WITH HOLES PLUGGED, KEY SWITCH AND LED'S NOT INCLUDED). MULTIPLE KEY STATION CAPABILITY (WITH ARMING INTERLOCK), EXIT/ENTRY PROTECTIVE CIRCUIT WITH SEPERATE ADJUSTABLE TIME DELAYS FOR EXIT AND ENTRY AND OUTPUT FOR ENTRY WARNING (SONALERT) SIGNALLING DEVICE, INSTANT PROTECTIVE CIRCUITS (BOTH INSTANT AND EXIT/ENTRY PROTECTIVE CIRCUITS HAVE INPUTS FOR CLOSED CIRCUIT OR OPEN CIRCUIT DEVICES). SLIDE SWITCH SELECTABLE RECYCLE/CUTOFF OPERATION WITH OPTIONAL PHASE II OPERATION, SEPERATE PANIC SWITCH AND HOLD-UP SWITCH OPERATION,

*
*

* * *
*

12v DC

@ 4 AMP BURGLAR ALARM OUTPUT FOR SIREN DRIVER OR BELL,

*
* *

ADJUSTABLE TIME DELAY FOR OPTIONAL (#1210) PLUG-IN POLICE CONNECT (OR DPDT) DRY CONTACT DIALER TRIP) OUTPUT RELAY, AUXILLIARY 12v DC POWER OUTPUTS FOR POWERING MOTION DECTECTORS, SMOKE
DETECTORS) RF PANIC RECEIVERS, DIGITAL DIALERS, ETC,
SEPERATE FIRE ALARM 12v DC BEL~ OR SIREN DRIVER OUTPUT, DRY RELAY CONTACT OUTPUT, (FOR DIALER TRIP, ETC,) AND FIRE ALARM PROTECTIVE CIRCUIT AVAILABLE VIA OPTIONAL (#1210) PLUG-IN RELAY, OPTIONAL

*
*

FS-21 FIRE ALARM SUPERVISORY MODULE AVAILABLE,

VARIOUS OTHER SOLDER PIN AND JUMPER OPTIONS (SEE TECHNICAL DATA SHEETS), ALSQTHE FOLLOWING FEATURES TO PROVIDE EASE OF SYSTEM INSTALLATION AND SERVICE:

* *
*

POWER CUTOFF SWITCH WITH OUTPUT FOR OPTIONAL SWITCH STATUS INDICATOR, CIRCUIT BOARD MOUNTED
~

STATUS INDICATOR LED,

CIRCUIT BOARD MOUNTED LOOP STATUS INDICATOR LED,

',,'

Sheet 2 of 6, (CU-22)

PHASE I I POST

0

CUTOFF MONITOR POST

C

OD

NORMAL

RECYCLE/CUTOFF

D
J3 SILENT PANIC J4 SILENT BURG.
r-' ;,.

POl-IER OFF MONITOR POST
B

o '"

I

J2 BELL SLAVE

I

~

Jl LOOP RESPONSE EXIT

o

'" 3:
t'l o

i· I ·
RELAY "A" DELAY

O

~

S
A

I~ ~OWER
~
Of)

15'"

-

'"

ENTRY

t =J

dO
~

'I

'

BD. MOUNTED STATUS LED'S

IIC MONITOR POST

o

CUTOFF SWITCH BOTH JUMPERS MARKED "S" MUST > BE CUT FOR SW. TO OPERATE EJELIIY DRY
"B"

G

r r I'E/PMJ r('
:d-~sr:T

12 VOLTS Ill'

DRY FIRE CONTACTS
,...,

~
r-'

C1

'"

~

'" C1
t"

""= C1
EARTIT GROUND BELL

0 0

0 0

"0

"0

+
BURGLIIRY I3CLL

..,
H

n

SMOKE POWER

'"
o o
r-' "0

ITOLDUP

+-----------'

OPEN CIRCUIT CONTACTS POLICE CONNECT REVERSING RELAY HOOKUP

RELAY "B" MUST BE INSTALLED FOR THE FIRE CIRCUIT TO OPERATE

37 I\UXILIARY POWER
8+

TERMINALS
6
8+

POWER REMOVED WHEN RESET BUTTON IS PUSHED REGULATED 12V DC 200 MA CONSTANT POWER REGULATED 12V DC CONSTANT POWER FILTERED/UNREGULATED 12v
DC MAX. IV P TO P RIPPLE @
500 MA MAX. 500 MA DRAIN 100 MA

USE FOR SMOKE
DETECTORS ONLY
USE FOR R.F. RECEIVERS, ETC. USE FOR MOTION DETECTORS DIGITAL DIALERS ETC.

LEASED LINE

38

TERMINALS
3 29+

+


TERMINALS
11

22

CU-22

CONTROL PANEL

Specifications SIZE: CABINET P.C. BOARD 11 x 15 x 4 inches 10.75 x 6.75 x 1.25 inches

ENVIRONMENTAL TEMP. LIMITS STANDBY CURRENT (TYPICAL) @13.6V Disarmed: Armed: Key Station #6730 Smoke Detector STANDBY TIME Loops closed 7SMA Loops open S8MA Loops closed 7SMA Alarm 90MA 2SMA key station SMA smoke detector

with 2.6 AH battery @ l3.6V Load Current (Total sum of all loads) Standby Time 25 20 17 1.2 10 7 5 hrs. hrs. hrs. hrs. hrs. hrs. hrs.

*This represents a typical system with 2 key stations and 3 smoke detectors.

100MA* l25MA l50MA 17 5~1A 200MA 300MA
400~1A

MAXIMUM RESISTANCE

DELAY PERIODS

FIRST WARNING SIGNAL BURGLARY BELL OUTPUT FIRE BELL OUTPUT BURGLARY CONTACTS FIRE CONTACTS AC PO~VER SMOKE DETECTOR POWER

500 ohms 500 ohms 250 ohms SO ohms SO ohms SO ohms 100 ohms 100 ohms 3 to 90 seconds 3 to 90 seconds Recycl~/Cutoff 10 minutes + S minutes Auxiliary Relay 1 to 90 seconds' 30MA maximum (3 G/A #6280 sonalerts) 4 amperes @ 12 to 17 VDC 1 amperes @ 12 to 17 VDC Relay "A" installed - 2 Form C (OPDT) SA '@ 28V resistive· load Relay "B" installed - 1 Form C SA @ 28V resistive load l2VAC ~ lVAC 40VA transformer (G/A #1240) Regulated @ l2VDC 300MA maximum

Premise Loop Exit Loop Panic Fire Hold-up Phase Two Reset Mat or Open Circuit Exit Entry

Sheet 3 of 6 (CD-22)

CIRCUIT BOARD FEATURES AND OPTIONS POTENTIOMETER ADJUSTMENTS Exit Delay Adjustment - PI The exit delay is the period of time that the exit loop may remain open (violated) once the panel is armed without causing the panel to latch into the entrance cycle. The exit delay starts immediately when the panel is armed. (Time is installer adjustable 3 to 90 seconds. Delay is increased by rotating potentiometer thumbwheel to right,) If the exit loop is violated after the exit delay has expired, the panel will "then latch into the entrance delay cycle even if the loop is subsequently closed. If the panel is not dis armed before the end of the cycle, the alarm will sound. (Time is installer~adjustable 3 to 90 seconds. Delay is increased by rotating potentiometer thumbwheel to right.) The police connect relay activation may be delayed up to 90 seconds from the time the panel is tripped into alarm condition. (The delay is installer-adjustable I to 90 seconds. Delay is increased by rotating potentiometer thumbwheel to right.) This delay does not effect the instant operation of this relay by hold-up or panic circuits. Recycle/cutoff position: - When the panel is armed and is tripped into alarm conditon, the siren will sound for approximately ten minutes. After this time, if the loops are restored, the panel will recycle and continue to protect the premises. If a loop is open, the bell or siren will shut off and the panel will indicate its cutoff with an output on post D. (See solder post "0" option) If the loop is restored at a later time, the panel will recycle. (See Phase Two solder post option for operation in cutoff condition) Normal Position: - An alarm will sound continously until the panel is reset at the key station. Armed Status (Red)
LED
Loop Status (Green)
LED
Power Disconnect
Service Switch
Mounted on circuit board to provide ease of installation, testing, and servicing of system.

Entry Delay
Adjustment - P2


Relay "A"
Adjustment - P3


Recycle/Cutoff
Normal Selector
Switch


Optional Operation: - Cut both "5" jumpers to make operational. This switch disconnects both AC &DC from the control panel for ease in servicing system, etc. Disconnect switch is also designed to provide remote switch status indicator capability. (See solder 'post "B" option)

(Circuit Board Features and Options continued)

Solder Post Options Solder Post "A" provides voltage output for optional remote AC status LED (#2240) indicator. (Hook up LED cartridge between solder post A- and terminal #33+). Solder Post "B" provides voltage output when power disconnect switch is in the "off" position for optional remote switch status LED (#2240) indicator. (Hook up LED cartridge between solder post B+ and terminal '#11-). Solder Post "C" (see sheet 3 Phase Two operation) Solder Post "0" provides an output only when the panel is in the cutoff Various indicator hook ups are as follows: 1: Connect solder post "0" to terminal #19.
(hold-up input) This will latch police
connect relay into alarm condition while
the panel is in cutoff.
2. Connect solder post "D" to terminal #34
(loop status indicator light). This will
light the status indicator while panel is
in cutoff.
Connect solder post "D" to terminal #30
(first warning sonalert). This will sound
sonalert while panel is in cutoff.

mod~

of operation.

3.

JUMPER OPTIONS Burglary Loop Response Jumper #1 (white) Fire & Burglary Bell Slave Jumper #2 (red) Silent Panic Option Jumper #3 (yellow) Silent Burglary Option Jumper #4 (blue) This jumper, if cut, allows a fast response time (approximately 10 milliseconds) needed for vibration switches, etc. (Premise loops only - terminals 15 & 16 or 17, & 18.) This jumper, if cut, slaves the burglary bell output to the fire bell output. The burglary bell operates normally; however, if the fire bell is activated, the burglary bell will also ring to provide maximum sound. This jumper, if cut, makes the panic circuit silent (no bell or siren driver output). Relay "A" will operate instantly. This jumper, if cut, makes the burglary circuit silent (no bell or siren driver output). Relay "A" will operate after the delay period set by pot P3 has expired.

Sheet 4 of 6 (CU-22)

PHASE II OPERATION - Solder Post-C Option

PHASE II POST

CU-22 CONTROL PANEL
Hook up #1

11
Interface with motion detector, etc. Tied into protective circuit loop.

15

16

MOTION DETECTOR CONTACTS

Operation - Phase II tie-in will not affect normal panel operation; however when panel is in cutoff mode of operation, any contact closure between terminals #15 and #11 will put the panel into a latched alarm condition.

PHASE II POST

CU-22 CONTROL PANEL
11

Hook up #2 Interface with motion detector, etc. Tied into exit/entry loop.

31

32

OPEN CIRCUIT CONTACTS

MOTION DETECTOR CONTACTS

Operation - Same as with hook up #1 ex~ept if the exit/entry loop is open when panel is in cutoff mode, any contact closure between terminals #31 and 11 will put the panel into alarm condition after the exit/entry time expires.

TERMINAL FUNCTIONS
TERMINALS
1

FUNCTION AC Power

DESCRIPTION 12 Volt AC Power - connect to #1240 transformer supplied with panel. WIRE SIZE TABLE - based on maximum currents Distance to Panel Wire Size o - 10' 18 GA 10 - 25' 16 GA over 25' not recommended - try to locate outlet closer to control Connect to earth ground. (cold water pipe or electrical ground)

&2

3
3

Ground Standby Power Gel/Cel Charger Smoke Detector Power

& 4

Connect terminal 3 to negative terminal of battery; connect terminal 4 to positive terminal of battery. NOTE: for re chargable battery, see terminalS below. When using a Gel/Cel, jumper terminals 4 & 5. This connects the built-in charger to the positive side of the battery. l2VDC regulated 300MA maximum continous drain. Connect l2V smoke detectors to terminal 8 positive and terminal 6 negative. Voltage is removed from these terminals when the reset button is depressed. NOTE: 12 Aritech FS602 smoke detectors may be connected to these terminals. These terminals allow the addition of remote reset buttons to reset the fire or panic circuits. NOTE: Use only normally open momentary switches. *RELAY "B" MUST BE INSTALLED. Always armed - connect a pair of wires to terminals 8 & 9 run them from fire sensor to fire sensor. Maximum loop resistance with any fire sensor closed is 50 ohms. The reset button must be depressed to reset the fire circuit. Terminals 10 & 11 Maximum available

5

6

& 8

7

& 8 & 9

Remote Reset Fire*

8

10 & 11

Fire Bell * *RELAY "B" MUST BE INSTALLED. Fire Bell l2VDC. provide l2VDC when the fire circuit is tripped. current 1 ampere.

12,13,14

Fire
*RELAY "B" MUST BE INSTALLED. Terminals 12 & 14 are normally closed Contacts*
and open when the fire circuit is tripped. Terminals 12 & 13 are normally open and close when the fire circuit is tripped. NOTE: The fire circuit is independent from the Panic & Burg circuits. If you desire to have the fire circuit activate the police connect relay, you must jumper terminal 12 to terminal 22; and terminal 13 to terminal 19.

I

Sheet 5 of 6 (CU-22)

TERMINAL FUNCTIONS (cont.) TERMINALS FUNCTION DESCRIPTION Supervised - normally closed contacts - wire normally closed con tacts in series from terminal 15 to 16 or in series from terminal 17 to 18 (maximum resistance in both loops 500 ohms).

~~ ~~ ]
15

:

Burglary Loops

& 22 & 22 & 33'

Burglary Unsupervised - normally open contacts - (mat circuit) wire normally Open-Circuit open contacts from terminal 15 to terminal 22 (maximum loop reContacts sistance with any contact closed is 100 ohms) Hold-up Loop Panic Loop Always Armed- Silent alarm (no bell output)- Use normally open latching hold-up switch; its closure activates police connect (optional) Relay "A" instantly. Unsupervised - use a normally open switch between these two terminals. Closing the switch activates the bell output and optional Relay "A" instantly. The reset button must be depressed to reset the panic circuit. Connect l2VDC siren driver or alarm bells across terminals 21 Terminal 21 is positive and 22 is negative.

19

20

21 29

& 22 &30

Burglary. Bell First Warning Signal

& 22.

Wire lamp or #6280 sonalert to these terminals (30 negative, 29 positive) (maximum 30MA). The First Warning Signal occurs the instant the exit/entry starts timing on the entry. delay. It is very useful in preventing operator-caused false alarms. A. If the operator is slow leaving (exit loop is opened after exit delay has elapsed), the first warning will signal the need to reset the control and re-arm the panel to allow new delay period. Upon entering, it warns that the system is armed and timing towards an alarm. No outside keys or status lamps are necessary.

B.

31

& 32

Exit/ Entry Loop (Closed Circuit) Exit/ Entry Loop (Open Circuit) Loop Status

Supervised - wire only closed circuit contacts in this loop. Maximum loop resistance is 500 ohms. (any contacts violated on exit/entry should be wired to this loop.) Unsupervised - Any open circuit devices that must be violated on Exit/Entry (such as mats) should be wired in parallel to these. terminals. This green lamp is lit when all loops are in the normal or no alarm condition. Connect loop status lamps or LED with 680 ohm resistor across terminals 33 positive and 34 negative. Maximum: 5 - #6730.

31 & 11

33; & 34

1-'


TERMINAL FUNCTIONS (cont.) TERMINALS 33 FUNCTION Armed Status Lamp DESCRIPTION This lamp (red) is lit when the Burglary section is on (armed). Connect armed status lamps or LED with 680 ohm resistor across terminals 33 positive and 35 negative. Maximum: 33 & 36 Key Switch 5-6730

& 35

Normally Open Momentary Switch: Closing the key switch or applying positive voltage to terminal 36 will arm & disarm the control panel. NOTE: This panel is equipped with arming interlock. This feature prevents arming the control panel (armed lamp on) unless the loop status lamp is on (all loops safe). This prevents .arming and causing a false alarm. NOTE: If a positive voltage greater than 2 volts is left on terminal 36 continously, the panel will arm when the loops are closed. With Relay "A" installed, terminals 37 & 39 are closed. When an alarm occurs, terminals 37 & 39 open and terminals 37 & 38 close. With Relay "A" installed, terminals 40 & 42 are closed. When an alarm occurs, terminals 40 & 42 open and terminals 40 & 41 close. *RELAY "A" MUST BE INSTALLED. Connect terminals 38,42, and 43. Connect erminals 39, 41, and 22. Terminals 37 and 40 are the leased line terminals. Terminal 37 is negative and terminal 40 is positive. During an alarm, the terminals change polarity. Leased line power. Short circuit protected. Maximum current 50MA maximum output voltage l8V. (See wiring diagram for terminal cross wiring)

37,38,39 40,41,42 37,38,39 40,41,42 43
43

Relay "A" Relay "A" Police
Connect*


Leased Line

CU-22T TROUBLESHOOTING CHART SYMPTOM AC Power Lamp Off CAUSE AC Power Off Transformer out of socket AC power fuse blown Loop Status Lamp remains Off. Open protective circuit loop Ground fault ACTION TO TAKE Check circuit breaker. Test AC voltage at terminals 1 measure l2VAC ~ IV. Inspect fuse Fl.

Sheet 6 of 6 (CU-22)

&2

of control-it should

Remove both sides of loop and replace with a jumper one loop at a time to locate the defective loop. Remove both sides of loop and replace with a jumper. Check resistance from terminal 3 to all loops - both sides - to locate ground path. Minimum resistance acceptable to terminal 3 is 10,000 ohms.

Panel Falses on Power Failure No Standby Power

See No Standby Power below Battery dead Rechargable battery not connected properly Check battery voltage. Check to see that terminals 4 & 5 are j wnped. 1 & 2 for proper AC voltage - l2VAC + IV. Trip panel to check relay and fuse condition. at terminals 21 (positive) and 22 (negative). Check switch position and lubricate contacts. Check to see that delay Pot P3 is set to Check t.erminals Check voltage

Panel will n'ot go into alarm Panel will not recycle Relay "A" does not trip instantly Panel will not arm

No Voltage on Bell Terminal Recycle/Normal switch in
normal position
Pot P3 not set correctly Loop Status Lamp is off

a

delay

The control will not arm unless all the protection loops are closed and safe. Check Premise loops, Exit loops and mat circuits. If necessary, remove wires and replace with jumpers.

.'1'

CU-22T TROUBLESHOOTING CHART SYMPTOM Panel will not arm CAUSE Defective key switch

~(cont.)

(CU- 22 )

ACTION TO TAKE Measure voltage from terminal 3 to terminal 36. When key switch is activated, the voltage should read greater than 5 volts. In the normal condit~Qn ( key not activated), the meter should read 0 volts. Perform test directly above. Perform test above. If voltage is present on terminal 36 continously, the panel will arm itself when all the loops are closed. Check for wet or shorted key wires. Check on Form C key switches (Medico) that common (C) &normally open (N.O.) are used - not normally closed (N.C.) Install Relay "A" Install Relay "B" Check to see that the reset button is not jammed downward. Check remote reset buttons. Remove any wires on terminal 7; if problem is gone, it is wiring related - if problem remains, it is a board-related problem. Reconnect Jumper J2

Panel cannot be turned off Panel arms itself

Defective key switch Defective key switch

No Contact Closure on terminals 37 thr~ 42 Fire Circuit will not operate Fire or Panic Circuits will not latch

Relay "A" not installed Relay "B" not installed Reset Signal

Burglary Bell rings when Fire Circuit is tripped NOTE:

Jumper J2 is cut

If the above tests fail to locate the problem, consult your distributor or the factory for assistance. GUARD AWARE, INC., 277 Elm Street, Bridgewater, MA 02324 (617) 697-3356.

-~