MakeModelProblemSolutionDate
Found: 85
PhilipsMD2.22E"Digital scan" does not appear in the picture menuIn the direction for use is mentioned that in the picture menu the function 'Digital Scan' can be switched off. However during the picture modes; Super Zoom, 14/9, 16/9, subtitles an automatic the function 'Digital Scan' does not appear in the picture me14-09-04
PhilipsMD2.22E+5 V stand-by defective (also fuse 1580 defect)First check the +5 V supply panel before replacing the fuse. When the +5 V panel is defective, it could be that the +5 V becomes too high, which will damage the circuitry.14-09-04

PhilipsMD2.22EACI table filling stops when National Geographic Channel is foundReplace position 7202 on the TXT & control module by: 4822 900 11102 Software for non EPG sets 4822 900 11066 Software for -/58 sets 4822 900 11058 Softwrae for EPG sets REMARKS : IRIS symptom code 1262 14-09-04
PhilipsMD2.22EAlternating noise in wireless surround speakersAlternating noise when (moving) objects are between the TV set and the wireless surround box can be solved by deleting R3153 (1k5) of module 1403 of the transmitter panel in the TV set. The components on module 1403 are not indicated but pointing the modu14-09-04
PhilipsMD2.22EAudio supply repair kit MD2.2Audio supply repair kit MD2.2 ----------------------------- For service now there is an audio supply repair kit available. This repair kit can be ordered with codenumber 4822 310 11086.14-09-04
PhilipsMD2.22EBackground noise audible in the wireless surround speakersChange on the receiver module in the active surroud loudspeaker the following components: - delete position 3731 - add position 3729 (4k7; 4822 051 20472) - change position 3730 into 4k7 (4822 051 20472) REMARKS : IRIS symptom code 154214-09-04
PhilipsMD2.22EBad focus or focus varies in a new set or after CRT replacementPossible solution: Short circuit the focus and the G2 pins of the picture tube with the aquadag coating. Switch the set on for approximately 5 seconds. After this return the set to its original condition. Check if the focus adjusted normally. If not repla14-09-04
PhilipsMD2.22EBad start behaviour, ON and ST.BY LED flashingChange mains input voltage by a variac. When start problem increases with an input voltage that is only about 10% below normal, check or replace the supply optocoupler. With a good optocoupler an avarage set easily starts on 60% of normal mains voltage.14-09-04
PhilipsMD2.22EBlinking LED (set in protection)Set in I2C software protection due to problems with the I2C communication. Check pin 12 of connector I46 on the Audio Module (SCL line). Look for a badly soldered (oxidated) pin 12. Resolder pin 12 if required.14-09-04
PhilipsMD2.22EChange in OSD functionChange in OSD function ---------------------- During production the OSD function of the MD2.2xE sets has been changed with the introduction of new software. The old situation was that by pressing the OSD button for 5 seconds it was possible to change bet14-09-04
PhilipsMD2.22ECode number of position 7207 of the TXT-Control paCode number of position 7207 of the TXT-Control panel ----------------------------------------------------- The code number of position 7207 (UM62256EM-55LL) of the control panel is missing in the service manual. The code number is 4822 209 15179.14-09-04
PhilipsMD2.22ECodenumber informationCodenumber information ---------------------- Codenumber software IC7202 on TXT control panel Sets without full EPG (nextview) is 4822 900 11102 Sets with EPG (nextview) is 4822 900 11058 /58 sets with East Europe language cluster is 4822 900 11066 14-09-04
PhilipsMD2.22EColour shift of negative coloursDuring program changing or with start-up from standby it is possible that the situation of colour shift of negative colours appears. This phenomenon only disappears after switching off and on and is difficult to reproduce. Solution: Change position 7505 o14-09-04
PhilipsMD2.22EColoured circles in picture after switching onReplace on the LSP the following components: - R3502 from 10 Ohm into 2.2 Ohm (4822 052 11228) - R3531 from 2k2 into 4k7 (4822 116 52283) - C2513 from 100nF into 10uF (4822 124 41579) mounted with the - to the base of T7514 REMARKS : Introduce14-09-04
PhilipsMD2.22EControl knobs of sets with top control does not workCheck the soldering of connector B45 of the top control panel (W or X) If required resolder the pins of this connector and relief connector B45. 14-09-04
PhilipsMD2.22ECorrection to styling 130 of Product Survey 1997-4Correction to styling 130 of Product Survey 1997-4 -------------------------------------------------- The description of the code numbers 4822 466 10933 and 4822 466 10934 of position 3 of styling 130 in product survey 1997-4 is not correct. The correct d14-09-04
PhilipsMD2.22ECorrection to styling 152 of Product Survey 1997-3Correction to styling 152 of Product Survey 1997-3 (4822 727 21552) ------------------------------------------------------------------- The code number of the tuner cable mentioned in the parts list is not correct. The code number mentioned is of a tuner 14-09-04
PhilipsMD2.22ECorrection to the MD2.21E/MD2.22E/MD2.23E serviceCorrection to the MD2.21E/MD2.22E/MD2.23E service manual -------------------------------------------------------- The code number of the Line Repair kit as mentioned on page 67 of the service manual MD2.21E/MD2.22E/MD2.23E AA is not correct. The correct c14-09-04
PhilipsMD2.22ECrackling noise coming from the picture tubeCrackling noise coming from the picture tube during light/dark changes of the picture contents. Mount bleeder (4822 310 11113) between LOT and picture tube. If problem still exist Anti Crackling Coating (ACC) can be applied. The code number for this AC14-09-04
PhilipsMD2.22ECrackling noise coming from the picture tube during program switchingService solution; change the picture tube into 4822 131 11279 REMARKS :IRIS symptom code 214514-09-04
PhilipsMD2.22ECurtain effect just after a white vertical line (ringing phenomenon)To reduce the ringing phenomenon change the following positions on the Small Signal Panel: Position 4508 into 1k (4822 051 10102) Position 3537 into 1k (5322 117 12487) Position 3538 into 1k (5322 117 12487) Position 3565 into 1k (4822 051 10102) Po14-09-04
PhilipsMD2.22EDigital picture when dynamic contrast is on.Check and replace if necessary AI panel. AI S/L 4822 212 11202 AI S/P 4822 212 11161 AI S/L/P 4822 212 11203 AI P 4822 212 11162 AI L 4822 212 11378 AI S/L/P PALPLUS 4822 212 11205 AI S/P PALPLUS 4822 212 11209 14-09-04

PhilipsMD2.22EDistortion in top of pictureCheck pins of connector J13 on the DDP. Look for badly soldered (oxidated) pins. Resolder pins if required. REMARKS : Improved connectors introduced in production from week 9742 onwards. 14-09-04
PhilipsMD2.22EDoes not start, during 15 sec. green LED ON, then red LED ON.Replace software IC7202 on TXT/Control panel codenr.: 4822 900 11058 and 4822 900 11066 for /58 sets. 14-09-04
PhilipsMD2.22EExtension cablesExtension cables ---------------- Service extension cables 4822 310 10674 can be used for servicing LSP and also for the feature box. 14-09-04
PhilipsMD2.22EFeature boxes in the repair procedureFeature boxes in the repair procedure ------------------------------------- The following feature boxes are now also in the repair procedure: 4822 212 11143 FBX3 smartic panic 4822 212 11198 FBX3 smartic limeric 4822 212 11204 FBX4 smartic limeric panic 414-09-04
PhilipsMD2.22EFlashing red LED, protection, intermitting failures.Check on +5 V panel the soldering of C2350. Also check and resolder pin 1,2,3, and 10,11,12 of connector V50 on the LSP.14-09-04
PhilipsMD2.22EGreek characters in Teletext.Change software into the following version: Non EPG sets: V_3104 317 00860; 4822 900 11102 EPG sets : V_3104 317 00890; 4822 900 11058 -/58 sets : V_3104 317 00870; 4822 900 11066 REMARKS : Introduced in production from week 9737 onwards.14-09-04
PhilipsMD2.22EHorizontal (colour or black/white) stripesCheck the connector (O55) of the combfilter. Resolder on the small signal panel but also at the comb-filter PCB. 14-09-04
PhilipsMD2.22EHorizontal jitter or sync faults during text-dualScreen mode.1. Switch the set on and let the set warm-up for about 1 hour with the rear cover mounted and eventually covered with a cloth. 2. Adjust L5465 in the following way: - turn L5465 to the left till the picture is out of sync. - turn L5465 to the rig14-09-04